2022 Sampling Results - Aurora
Village of Aurora
Fluridone Monitoring Report
Samples Collected by Cayuga County Health Department
Samples Analyzed by CSI Laboratory
Sample Collection Date | Drinking Water Sample Collected from Distribution System 1 | Bathing Beach Sample Collected from Wells College Dock |
---|---|---|
7/1/2022 | <0.5 | N/A |
7/11/2022 | <0.5 | N/A |
7/20/2022 | <0.5 | N/A |
7/25/2022 | <0.5 | N/A |
8/1/2022 | <0.5 | N/A |
8/8/2022 | <0.5 | N/A |
1 Samples collected from Wells College Maintenance Building unless otherwise noted
Units are in µg/L (micrograms per liter)
Test method: Modern Water RaPID Assay Fluridone Test Kit
NYSDOH Maximum Contaminant Level is 50 parts per billion. For more information, go to Fluridone FAQs (PDF) .
Fluridone Monitoring Report
Samples Collected by E&E (Ecology and Environment, Inc.)
Samples Analyzed by SePro
For a map of the locations that correspond with location ids below, click here.
Sample Collection Date | Lake N | Lake S | ND1 | ND2 | NS1 | NS2 | NS3 | NS4 | NS5 |
---|---|---|---|---|---|---|---|---|---|
7/1/2022 | <1 | <1 | 1.1 | <1 | 1.7 | <1 | 1.2/1.4 | 3.2 | 2.2 |
7/8/2022 | <1 | <1/<1 | 3.5 | 1.2 | 2.8 | 3.7 | <1 | <1 | 1 |
7/15/2022 | <1 | <1 | 5.6 | 1.8 | <1 | <1 | <1/<1 | <1 | <1 |
7/22/2022 | <1 | <1 | 6.6 | 2.4 | 7.8 | 1.7 | <1 | <1 | <1 |
7/29/2022 | <1 | <1 | 16.2 | 1.5 | 3.4 | 1.7 | 1.3 | <1 | <1 |
8/5/2022 | <1 | <1 | 2.4 | 2.9/3.0 | 1.2 | 1.7 | 1.2 | 1.7 | <1 |
Units are µg/L (micrograms per liter)
Bold values denote positive detections
Two reported results in a single cell indicate an instance where a field duplicate sample was collected.
Test method: Proprietary
Fluridone Monitoring Report
Samples Collected by Solitude
Samples Analyzed by SePro
For a map of the locations that correspond with location ids below, click here.
Sample Collection Date | SS4 | SD1 | SS3 | SS2 | SS1 | LP1 |
---|---|---|---|---|---|---|
7/1/2022 | 1.7 | <1 | 3.1 | <1 | <1 | 1.5 |
Units are µg/L (micrograms per liter)
Bold values denote positive detections
Test method: FAST 10
Fluridone Monitoring Report
Samples Collected by Solitude
Samples Analyzed by CSI Laboratory
For a map of the locations that correspond with location ids below, click here.
Sample Collection Date | SS4 | SD1 | SS3 | SS2 | SS1 | LP1 |
---|---|---|---|---|---|---|
7/8/2022 | <0.5 | 1.9 | 3.2 | 11.1 | 8.1 | 1.1 |
7/15/2022 | 4.4 | 4.7 | 1.1 | 2.7 | 2.2 | <0.5 |
7/22/2022 | 6.0 | 1.6 | 1.5 | 2.7 | 2.8 | <0.5 |
7/29/2022 | 2.9 | 1.2 | 2.6 | 1.6 | 1.5 | <0.5 |
Units are µg/L (micrograms per liter)
Bold values denote positive detections
Test method: Modern Water RaPID Assay Fluridone Test Kit
Copper Monitoring Report
Samples Collected by E&E (Ecology and Environment, Inc.)
Samples Analyzed by ALS Environmental
Sample Collection Date | Location | |
---|---|---|
Units are in parts per million.
NYSDOH action level for copper is 1.3 parts per million.
Analysis method was EPA 6010C.
Copper Monitoring Report
Samples Collected by Cayuga County Health Department
Samples Analyzed by Life Science Laboratories, Inc.
Sample Collection Date | Drinking Water Sample Collected from Distribution System 1 |
---|---|
1 Samples collected from Wells College Maintenance Building unless otherwise noted.
Units are in parts per million.
NYSDOH action level for copper is 1.3 parts per million.
Analysis method was EPA 200.8, Rev 5.4